Home / HL200 Headlight Tester / OSRAM H4 Halogen Test

Documented automotive headlight bench test · November 19, 2026

OSRAM H4 Halogen Headlight Test: Low & High Beam Lux and 5-Minute Stability

What can a fixed-point illuminance measurement tell us about a conventional halogen H4 bulb? We installed an OSRAM H4 halogen bulb in a headlamp housing, recorded independent low- and high-beam readings with the Letrava HL200, then switched back to low beam for a 4-minute-38-second Continuous Test.

OSRAM H4 · halogenOriginal filmingLux + CCTSeparate beam sensor positionsLow beam: 4m 38s
Real OSRAM H4 halogen headlight test footage, HL200 sensor and live measurement app; English test cover
388 lx
Low-beam live snapshot

3377 K CCT · low-beam sensor

223 lx
High-beam live snapshot

3504 K CCT · high-beam sensor

+0.7%
APP-indicated change

Low-beam Continuous Test · 4m 38s

These live Lux snapshots are readings from different sensor positions in different beam modes. The larger low-beam number does not mean the halogen bulb emits more total light on low beam.

Watch the real test ↓See the measured data ↓

01 / Original filmed demonstration

Watch the OSRAM H4 halogen test

A 96-second English edit assembled from the original test recordings: bulb inspection, installation, test geometry, separate low/high-beam observations and the complete low-beam Continuous Test shown at accelerated playback.

Download or open test video (MP4)

The approximately 4m 38s low-beam recording is sped up for viewing. This is not a real-time 96-second test.

02 / Measurement method

One H4 bulb, one headlamp housing, and fixed test points

We documented the OSRAM H4 halogen bulb, fitted it into the test housing, checked an approximately 3 m bench-test separation with a tape measure, then used the HL200 at its set sensor location. The sequence of beam-mode changes matters when reading the phone display.

STEP 01

Install the halogen bulb

The OSRAM H4 bulb and housing are shown in original footage. This is a bench demonstration, not an on-road beam-compliance test.

STEP 02

Measure low and high separately

Use the orange LOW BEAM field while the low beam is on; use the blue HIGH BEAM field after switching to high beam.

STEP 03

Switch back to low beam

Only after returning to low beam do we record the roughly five-minute low-beam Continuous Test.

Original video of OSRAM H4 halogen bulb being handled during bench test
Real OSRAM H4 bulb from the test recording, not a 3D rendering.
Tape measure checking approximately three meter bench-test distance
Measurement geometry checked with a tape. Lux results belong to this particular arrangement.
Why the test geometry matters: Lux is illuminance reaching a sensor, not a measurement of the lamp's total lumens. Distance, aiming, beam distribution, ambient light and sensor alignment influence the readings. There was no independent full-beam photometric grid or road-legal compliance assessment.

03 / Live readings

Low beam: 388 lx. High beam: 223 lx. Different points—not a brightness contest.

The two example frames below show the active beam field in the HL200 phone interface. We identify the correct field instead of mixing in values retained in the non-active beam panel.

Recorded momentBeam mode & active sensorIlluminanceCCT
Live low-beam snapshotLow beam ON · orange LOW BEAM field388 lx3377 K
Live high-beam snapshotHigh beam ON · blue HIGH BEAM field223 lx3504 K
Actual HL200 phone app low-beam field showing 388 lux and 3377 K correlated color temperature
LOW BEAM ON: 388 lx / 3377 K in the orange LOW BEAM field. The blue field above does not define the active low-beam observation.
Actual HL200 phone app high-beam field showing 223 lux and 3504 K correlated color temperature
HIGH BEAM ON: 223 lx / 3504 K in the blue HIGH BEAM field. The orange field below is not the basis for this high-beam reading.
Do not compare these two Lux numbers as whole-lamp output: the 388 lx and 223 lx values were collected at separate sensor positions intended for different beam patterns. They cannot establish which beam emits more total light, which performs better on the road, or whether a headlight meets regulatory requirements.
Real photographed low-beam headlight spot and HL200 sensor on tripod
Low-beam pattern at the fixed sensor position. No artificially generated beam image.
Real photographed high-beam spot on wall during OSRAM H4 test
High-beam pattern from the replacement original filming. Beam mode changed before taking the high-beam reading.

04 / Returned to low beam

What happened during 4 minutes 38 seconds of low-beam operation?

The headlight was switched back to LOW BEAM before the timed test began. The video then shows the complete approximately five-minute phone recording at accelerated playback, followed by the captured summary screen. No separate high-beam Continuous Test was made for this article.

HL200 app fieldRecorded low-beam resultInterpretation
Duration4 min 38 sec (278 s)Original continuous segment length
Maximum (MAX)393 lxHighest observed lux in this run
Minimum (MIN)363 lxLowest observed lux in this run
Average (AVG)379 lxAverage reported by the app
Current at captured end378 lxFinal reported instant reading
APP-indicated change+0.7%App comparison to its own starting reference
Actual end of 4 minute 38 second HL200 low beam continuous test showing MAX 393 MIN 363 AVG 379 CURRENT 378 and app 0.7 percent increase
The APP's final summary screen, as captured in the original low-beam Continuous Test footage.

Does +0.7% mean the lamp varied by only 0.7%?

No. The APP's displayed +0.7% is a reference-to-current calculation. The recorded maximum was 393 lx and the minimum was 363 lx, a 30 lx observed range over the test.

That range equals approximately 7.6% of the recorded MAX (30 ÷ 393 × 100). The max-to-min spread and the APP's reference-to-current figure answer different questions.

The final 378 lx was close to the app's starting reference according to the +0.7% indicator, but the footage alone does not establish the cause of every fluctuation. It is a single documented bench run.

Download the measurement summary CSV ↓

CSV contains manually transcribed summary figures from the recording. It is not a raw time-series export or a device-generated CSV.

05 / What the numbers mean

What we learned—and what this test cannot prove

  • In one filmed low-beam snapshot, the OSRAM H4 setup produced 388 lx at the low-beam sensor (3377 K CCT).
  • In one filmed high-beam snapshot, it produced 223 lx at the high-beam sensor (3504 K CCT). These are different measurement points.
  • With the system back in low-beam mode, the 4m 38s Continuous Test reported MAX 393, MIN 363, AVG 379 and CURRENT 378 lx, plus APP +0.7%.
  • The results do not measure the full luminous flux of the lamp, certify the beam for road use, or establish that this sample represents every OSRAM H4 bulb.
Independent test context: OSRAM is a trademark of its respective owner. The OSRAM H4 lamp was used as a test subject; this article is not presented as a manufacturer-sponsored evaluation or OSRAM certification. HL200 is the Letrava measuring instrument.

06 / Frequently asked questions

Questions about this H4 halogen test

Why was the recorded low-beam lux value higher than the high-beam value?

Because these values represent different HL200 sensor positions under different beam patterns. They are not a same-point test of total beam brightness and should not be used to infer total lumens or driving performance.

Was the five-minute test on low beam or high beam?

Low beam only. The system was switched back to low beam before recording the original 278-second Continuous Test. No high-beam five-minute record is claimed.

What does the APP's +0.7% mean?

It is the change shown by the APP relative to its starting reference at the end of the low-beam run. It is not the difference between the maximum and minimum values, and it is not a total-lumen measurement.

Is this proof the headlight meets automotive lighting regulations?

No. The test documents a single bench setup at specific sensor positions. Regulatory evaluations require defined photometric patterns, positioning, calibrated equipment and applicable prescribed procedures.